The ProLinx DNP 3.0 Master to PROFIBUS DP Slave Gateway creates a powerful connection between devices on a DNP 3.0 network and PROFIBUS DP master devices. This stand-alone DINrail mounted protocol gateway provides one serial port and PROFIBUS DB Slave port.
The DNP 3.0 Master protocol driver supports Master implementations of the protocol on one port. This port is fully configurable.
The PROFIBUS DP Slave protocol driver supports the PROFIBUS V0 Slave implementation, providing powerful data transfer capability between the ProLinx module and Siemens PLCs or other hosts. User configurable data mapping and DP port operation make the interface an easy to use and powerful data transfer tool.
The DNPM-PDPS modules are the ideal solution for the many applications where DNP 3.0 Master connectivity can be used to integrate a PROFIBUS DP Slave device into a system. The DNP 3.0 Master gateway is a powerful module designed with Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the PROFIBUS device support, the module provides a very powerful interface to the many PROFIBUS devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially the Manufacturing, Oil and Gas, Electrical Power and Food Processing.
The DNPM-PDPS modules are the ideal solution for the many applications where DNP 3.0 Master connectivity can be used to integrate a PROFIBUS DP Slave device into a system. The DNP 3.0 Master gateway is a powerful module designed with Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the PROFIBUS device support, the module provides a very powerful interface to the many PROFIBUS devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
The ProLinx module contains an internal database that consists of areas for application data, status information, and configuration information.
The internal database is shared between all ports on the module and is used as a conduit to pass information from a device on one network to one or more devices on another network.
The data area is used to store and retrieve data by the protocol drivers and for data exchange between protocols. The database is used as a source for write commands to remote devices and holds data collected from the remote devices. Commands defined in the configuration file (stored in the configuration data area) control how the data is to be handled in the database.
This area is used to store error codes, counters, and port status information for each port.
This area contains module configuration information such as port configuration, network information, and command configuration. This configuration file is downloaded to, or uploaded from, this area.
Specification | Description |
Power Supply |
24 VDC nominal |
Current Load | 500 mA max @ 32 VDC max |
Operating Temperature | -4° F to 122° F (-20° C to 50° C) |
Storage Temperature | -40° F to 185° F (-40° C to 85° C) |
Relative Humidity | 5% to 95% (with no condensation ) |
Dimensions |
Standard: |
LED Indicators |
Power and Module Status |
Configuration Serial Port |
DB-9M RS-232 only |
Ethernet Port (Ethernet modules only) |
10Base-T half duplex RJ45 Connector |
Application Ports |
Modbus Plus Connector |
Serial Port Isolation |
2500 V RMS port signal isolation per UL 1577 |
Shipped with Each Unit |
Mini-DIN to DB-9M serial cables |
ProSoft Configuration Builder (PCB) | ||
DNPM PDPS Datasheet | 347,86 kB | Zuletzt geändert 31.05.2013 |
DNPM Driver Manual | 552,06 kB | Zuletzt geändert 10.12.2009 |
PDPS Driver Manual | 684,88 kB | Zuletzt geändert 10.12.2009 |
ProLinx GSD File | 398,03 kB | Zuletzt geändert 11.05.2010 |
The DNP 3.0 Slave protocol driver supports Slave implementations of the protocol on one port. This port is fully configurable.
The DNP 3.0 Slave driver provides extensive support for Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DNP 3.0 protocol (Slave, Error Checking, Baud rate, etc).
General Parameters |
|
Internal Database | Binary Inputs: 0 to 500 word count Analog Inputs: 0 to 500 points Counters: 0 to 250 points Binary Outputs: 0 to 200 word count Analog Outputs: 0 to 500 points Binary Input Events: 0 to 100 event buffer Analog Input Events: 0 to 100 event buffer |
Communication parameters | Baud Rate: 110 to 115K baud Stop Bits: 1 Data Size: 8 bits Parity: None RTS Timing delays: 0 to 65535 milliseconds |
DNP Mode | DNP 3.0 Slave - Level 2 |
DNP Slave |
|
Node address | 0 to 65534 (software selectable) |
The module supports complete Master specifications according to IEC 61158. Acyclic parameter data can be transferred with Class 1 or Class 2 DPV1 services, allowing processors to easily communicate with slave devices supporting PROFIBUS DPV0/V1 protocol.
The ProLinx PDPMV1 PROFIBUS Master module acts as a PROFIBUS network scanner, transferring Input and Output data between PROFIBUS devices and the network.
PROFIBUS Master Specifications
PROFIBUS Master Port
The PROFIBUS DP Master protocol driver supports complete Master specifications according to IEC 61158 on either a Mono-Master or Multi-Master network. The module supports the DPV1 specification.
CB Safety | 35,78 kB | Zuletzt geändert 27.08.2012 |
Declaration of Conformity (RoHS/CE) | 299,94 kB | Zuletzt geändert 04.03.2018 |
Korean KC Registration | 851,60 kB | Zuletzt geändert 22.02.2013 |
Russian GOST-R | 7,07 MB | Zuletzt geändert 22.02.2013 |
GOST-R Declaration of Conformity | 6,68 MB | Zuletzt geändert 22.02.2013 |
UL/cUL; Class 1, Div 2 | 1,08 MB | Zuletzt geändert 02.07.2013 |
UL/cUL; Class 1, Div 2 (Canada) | 1,10 MB | Zuletzt geändert 02.07.2013 |