;************************************************************************* ;*** *** ;*** ProSoft Technology,Inc. *** ;*** PROFIBUS DP *** ;*** *** ;************************************************************************* ;*** *** ;*** Filename: PSFT0EE2.GSD (c) 2020 *** ;*** GSD file from 29.04.2020 *** ;*** *** ;************************************************************************* ; ;************************************************************************* ; Revision log: ; 1.00 - First release ; 1.01 - Remove info text from modules ; 1.02 - Remove Bitmap_Device with empty string ;************************************************************************* #Profibus_DP GSD_Revision = 5 Vendor_Name = "ProSoft Technology, Inc." Model_Name = "ILX56-PBM" Revision = "V1.0" Ident_Number = 0x0EE2 Protocol_Ident = 0 Station_Type = 0 Hardware_Release = "V1.0" Software_Release = "V1.0" Implementation_Type = "Implementation" 9.6_supp = 1 19.2_supp = 1 45.45_supp = 1 93.75_supp = 1 187.5_supp = 1 500_supp = 1 1.5M_supp = 1 3M_supp = 1 6M_supp = 1 12M_supp = 1 MaxTsdr_9.6 = 70 MaxTsdr_19.2 = 70 MaxTsdr_45.45 = 70 MaxTsdr_93.75 = 70 MaxTsdr_187.5 = 70 MaxTsdr_500 = 150 MaxTsdr_1.5M = 200 MaxTsdr_3M = 250 MaxTsdr_6M = 450 MaxTsdr_12M = 800 Redundancy = 0 Repeater_Ctrl_Sig = 2 24V_Pins = 0 Freeze_Mode_supp = 0 Sync_Mode_supp = 0 Auto_Baud_supp = 1 Set_Slave_Add_supp = 0 Min_Slave_Intervall = 6 Modular_Station = 1 Max_Module = 40 Max_Input_Len = 244 Max_Output_Len = 244 Max_Data_Len = 488 Max_Diag_Data_Len = 244 Max_User_Prm_Data_Len = 3 Ext_User_Prm_Data_Const(0) = 0x00,0x00,0x00 ; Reserved for DP-V1 Slave_Family = 0 Fail_Safe = 0 DPV1_Slave = 1 DPV1_Data_Types = 0 C1_Read_Write_supp = 1 C1_Max_Data_Len = 240 C1_Response_Timeout = 100 C2_Read_Write_supp = 0 C2_Max_Count_Channels = 0 C2_Max_Data_Len = 0 Max_Initiate_PDU_Length = 0 Extra_Alarm_SAP_supp = 1 Alarm_Sequence_Mode_Count = 0 Alarm_Type_Mode_supp = 1 Diagnostic_Alarm_supp = 1 Process_Alarm_supp = 1 Pull_Plug_Alarm_supp = 1 Status_Alarm_supp = 1 Update_Alarm_supp = 1 Manufacturer_Specific_Alarm_supp = 1 Ident_Maintenance_supp = 0 Module = "Input: 1 Byte" 0x90 1 EndModule Module = "Input: 2 Bytes" 0x91 2 EndModule Module = "Input: 4 Bytes" 0x93 3 EndModule Module = "Input: 8 Bytes" 0x97 4 EndModule Module = "Input: 16 Bytes" 0x9F 5 EndModule Module = "Output: 1 Byte" 0xA0 6 EndModule Module = "Output: 2 Bytes" 0xA1 7 EndModule Module = "Output: 4 Bytes" 0xA3 8 EndModule Module = "Output: 8 Bytes" 0xA7 9 EndModule Module = "Output: 16 Bytes" 0xAF 10 EndModule