ProSoft Technology, Inc. PROFIBUS comDTM 
Read Me
PROFIBUS comDTM Version 1.0.1.5 with Install Version 
1.02.0002 Readme File
Last updated on March 02, 2009

This README file contains information you should know before you install or 
upgrade to comDTM Version 1.0.1.5 with Install Version 1.02.0002. This file 
also contains information that may not be available in other ProSoft 
documentation. Visit for the most up-to-date information about the comDTM.
Table of Contents
comDTM - Compatibility
comDTM Operating Systems Tested
Introduction
System Recommendations
Installation Instructions
Instructions on Upgrading the ProSoft Technology COM-DTM
Upgrade Information
Detailed Reasons for Change
New Features
Known Issues & Limitations
Previously Released versions of ProSoft PROFIBUS 
comDTM
comDTM Compatibility
The following system requirements apply to comDTM.
comDTM installation instructions are provided in the comDTM Setup and 
Installation Guide.
Note: System requirements in this document are subject to change 
and do not represent a commitment to support any particular 
software or hardware.
comDTM Operating Systems Tested
*	Windows XP Professional Ver.2002 Service Pack 2 512 MB RAM Pentium 4 
(2.66ghz)
*	Windows 2000 Ver.5.00.2195 Service Pack 2 522.544 MB RAM PentiumIII 
(550mhz)
Introduction
The PROFIBUS comDTM enables connection between bus-connected field 
devices such as flow meters, actuators etc. and their associated slave DTMs 
through ProSoft related module. This is accomplished using the FDT 
technology, the ProSoft Technology PROFIBUS DPV1 master modules and the 
ProSoft PROFIBUS comDTM.
Typical FDT frame applications are Fieldcare (Endress & Hauser), PACTware 
(PACTware association) or fdtCONTAINER (MM-Software).
The ProSoft Technology PROFIBUS DPV1 master modules supports Class 1 
and 2 services thereby allowing for cyclic Class 1 services to co-exist with the 
acyclic comDTM Class 2 services on the same network.
The PROFIBUS comDTM allows the FDT container configured DTM's to connect 
to their associated field devices via a serial or Ethernet interface. Ethernet 
communications are recommended for speed, and when multiple connections 
are required.
Note: PTQ-PDPMV1 supports Ethernet only. Please do not use the 
serial port connection in the communication transport. 
MVI56-PDPMV1 supports Ethernet through CIPCONNECT with a 
1756-ENBT card in the same rack as the MVI56-PDPMV1 (firmware 
version 1.28.000 or later and comDTM version 1.0.1.5 with install 
version 1.01.0003 or 1.02.002. For information on how to check the 
comDTM version and install version, refer to Verifying the comDTM 
Version and comDTM Install Version in the comDTM Quick Start 
Guide.
The ProLinx PDPMV1 module supports comDTM access through 
Ethernet.
Other MVIXX-PDPMV1 modules provide support only for serial. There 
is only a physical serial port on the MVI.
System Recommendations
*	Windows 98 SE, NT 4.0, 2000, XP
*	2 MBytes free Hard Disk space
*	Pentium IV CPU
*	256 MB RAM
*	FDT 1.2.1 compliant FDT frame application installed
*	Ethernet NIC or
*	Serial interface port
*	ProSoft Technology Profibus DPV1 master module
Installation Instructions
1.	Install a standard FDT frame application, such as Fieldcare, PACTware or 
fdtCONTAINER.
2.	Install all desired field device DTMs.
3.	Install the comDTM. Select "Install PROFIBUS comDTM" from the 
software CD menu. Review the Getting Started guide for complete 
installation instructions.
4.	Select the "Getting Started " from the software CD menu.
5.	If the ProSoft Technology Master module has not been configured, follow 
the module's Setup Guide to configure the module and Ethernet or Serial 
port settings.
6.	Review the Getting Started guide for comDTM startup instructions. Select 
"Getting Started" from the software CD menu.
7.	Check for revision updates on the ProSoft Technology website for 
software updates - http://www.prosoft-technology.com or contact 
Technical Support at 661-716-5100
Important: CIPconnect functionality requires Microsoft .NET 2.0 
Framework. ProSoft Configuration Builder installer will prompt you to 
install .NET 2.0 if this component is not already present. If you do 
not wish to use the CIPconnect Path Editor, you can skip this portion 
of the installation. If you choose at a later time to use CIPconnect, 
please rerun the ProSoft Configuration Builder installer to install .NET 
framework v2 then ignore if the installer prompt to alter PCB 
installation.
Instructions on Upgrading the ProSoft Technology COM-
DTM
If your PC currently has installed ProSoft Technology COM-DTM version 
1.0.0.10 please uninstall this version through "Control Panel/Add or Remove 
Programs" before installing a newer version.
For any versions later than 1.0.0.10 you can run the setup for the new 
upgrade (there is no need to uninstall the current version through Control 
Panel).
Upgrade Information
Detailed Reasons For Change
*	Modified abmdpv.dll to allow diagnostic information for PCB
(Prosoft Configuration Builder) via CIPconnect.


PROFIBUS comDTM Version 1.0.1.5 
version 1.02.0001 (June 13, 2008)

Detailed Reasons For Change
*	Modified abmdpv.dll to allow Ethernet communication through a 1756-
ENBT card to the MVI56-PDPMV1 through the backplane of a ControLogix 
PLC. This feature is only supported for MVI56-PDPMV1 firmware version 
1.28.000 or later.
New Features
*	Option to now configure the PROFIBUS comDTM to allow communications 
through a rack mounted 1756-ENBT to the MVI56-PDPMV1 using 
CIPCONNECT.
Known Issues & Limitations
*	For Ethernet applications, only one PC can establish connection through 
comDTM at a time. The same PC can establish simultaneous connection 
with comDTM and PCB for PROFIBUS (Monitor/Modify to monitor the 
PROFIBUS network). Also, different PCs (up to 20) can simultaneously 
monitor the PROFIBUS network through PCB for PROFIBUS. But only one 
PC can access the comDTM at one time. (TEG2518)
*	If the user disconnects the Ethernet cable than the comDTM still shows its 
status as connected. The user needs to manually disconnect-reconnect 
the comDTM. (TEG 2519)
*	comDTM communication configuration screen does not show the IP 
Address configured for the 1756-ENBT and does not display the Slot 
number configured. Therefore the textual name must be used when 
coordinating the communications configuration with the ProSoft Transport 
Path Editor entry. 
*	comDTM communication configuration screen indicates the "Type" as a 
numerical value of '3' when using the CIPCONNECT type 
communications to the PDPMV1.
To utilize Ethernet communications to the MVI56-PDPMV1 you must 
have a 1756-ENBT or compatible module installed in the same rack 
as the PDPMV1. 
To use this feature, the MVI56-PDPMV1 firmware must be at 
1.28.000 or above.
Previously Released versions of ProSoft 
PROFIBUS comDTM
Version 1.0.1.5 (January 9, 2007)
Detailed Reasons for Change
*	Faulty disabled menu items Configuration, Offline Parameter and Online 
Parameter in combination with the frame application fdtCONTAINER 2.2. 
New Features
*	The option "Selection Communication Interfaces" was changed, now the 
software doesn't use the PDPMPtDg.dll library any longer. To 
create/change a transport path an own FDT conform OCX was 
integrated. So the extra window will not be displayed during the 
communication interface configuration.
Known Issues and Limitations
*	Adding the ComDTM to a project without previously installing any DTM 
libraries may cause an initialization error. The DTM libraries must be 
installed prior to adding the comDTM to the FDT container project (the 
comDTM can be installed though)
*	At the transport path configuration window: selecting the Delete button 
while there are no communication paths selected may crash Pactware
*	The Ethernet connection implements UDP which dynamically allocates a 
random local UDP port for every connection. This implementation will limit 
the possibility of using most serial-Ethernet converters to access the 
MVIxx-PDPMV1 serial port through a PC Ethernet connection. Most 
converters will require the configuration of a fixed UDP port which is not 
available for the current implementation. 
Version 1.0.1.3 (September 20, 2006)
Detailed Reasons For Change
*	Fixed reconnect issue after interrupting Ethernet/Serial connection (the 
module does not need to be rebooted after communication interruption)
*	Resource allocation problem while adding slaves in MultiUser based FDT 
frames fixed.
*	Handling of simultaneous connections to different modules corrected.
*	Installation error during software upgrade fixed. Now when upgrading 
from version 1.0.1.3 to a more recent version it is no longer required to 
uninstall the version first.
*	Correct version is displayed at FieldCare (the previous version used a 
specific internal file for displaying the version).
*	The new default IP address is 192.168.0.100 (instead of 0.0.0.0) and the 
new default COM port is COM1 (instead of COM0). This prevents the user 
to select an invalid transport path and crash the FDT container.
*	After deleting a communication path the Communication Interface 
Selection window will no longer display any record for the path.
*	Warning text before starting the transport path configuration utility 
changed from "Important informations in the FDT-Container may be 
covered" to "Important informations in the FDT-Container may be 
hidden".
New Features
*	Added support for serial connection to MVIxx-PDPMV1 modules (please 
refer also to Known Issues & Limitations section for observation 
regarding the use of Ethernet-serial converters)
*	User administration implemented: depending on the FDT frame logged in 
user level, different configuration functions are enabled/disabled.
*	Automatic network setup in connection with on line scan: no address 
dialog is opened if online scan and automatic network configuration is 
used. The DTM address is automatically assigned from the scanned live 
list instead.
*	The list of transport paths in the comDTM's configuration utility is 
automatically updated after closing the transport path configuration utility 
(it is no longer required to select the Refresh option)
Known Issues
*	Adding the ComDTM to a project without previously installing any DTM 
libraries may cause an initialization error. The DTM libraries must be 
installed prior to adding the comDTM to the FDT container project (the 
comDTM can be installed though)
*	At the transport path configuration window: selecting the Delete button 
while there are no communication paths selected may crash Pactware
*	The Ethernet connection implements UDP which dynamically allocates a 
random local UDP port for every connection. This implementation will limit 
the possibility of using most serial-Ethernet converters to access the 
MVIxx-PDPMV1 serial port through a PC Ethernet connection. Most 
converters will require the configuration of a fixed UDP port which is not 
available for the current implementation.
Version 1.0.0.10 (September 7, 2006)
Known Issues
1.	Deleting a communication path will not clear it from the Communication 
Interface Selection window (displayed as Not Used).
2.	Installing a newer version over version 1.0.0.10 will cause an error 
message during installation procedure. Version 1.0.0.10 needs to be 
uninstalled first (through Control Panel) before installing a newer version.
3.	Supports only one COM-DTM connection for a FDT container session 
through auto-scan (to automatically detect the connected slaves). Using 
more than one connection will cause the connections to mix devices.
4.	Auto-scan option forces the user to enter the slave addresses for each 
slave (Create Network option for FieldCare).
5.	Selecting an IP address of 0.0.0.0 (default but invalid) causes the FDT 
container to crash.
6.	Disconnecting the cable during communication will require the module to 
be rebooted to re-initialize communication.
August 22, 2006
Updated license agreement in documentation.
July 7, 2006
Updated documentation to clarify license agreement with regard to hot 
standby and server installations. No change to software.
Copyright  ProSoft Technology, Inc. 2000 - 2008. All Rights Reserved.