The ProLinx Modbus TCP/IP to PROFIBUS DP Slave Gateway creates a powerful connection between devices on a Modbus TCP/IP network and a PROFIBUS DP Master device. This stand-alone DIN-rail mounted protocol gateway provides a single Ethernet port and a single DB9F PROFIBUS port.
The Modbus TCP/IP protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNET driver supports Client and Server connections, and when coupled with the Web option provides a web/ftp interface as well.
The PROFIBUS DP Slave protocol driver supports the PROFIBUS V0 Slave implementation, providing powerful data transfer capability between the ProLinx module and Siemens PLCs or other hosts. User configurable data mapping and DP port operation make the interface an easy to use and powerful data transfer tool.
The MNET-PDPS modules are the ideal solution for the many applications where Modbus TCP/IP connectivity can be used to integrate a PROFIBUS DP Slave device into a system. The Modbus TCP/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to other Modbus TCP/IP devices (Modicon processors and many others). In combination with the PROFIBUS DP device support, the module provides a very powerful interface to the many Modbus TCP/IP devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially the Manufacturing, Oil and Gas, Electrical Power and Food Processing.
The MNET-PDPS modules are the ideal solution for the many applications where Modbus TCP/IP connectivity can be used to integrate a PROFIBUS DP Slave device into a system. The Modbus TCP/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to other Modbus TCP/IP devices (Modicon processors and many others). In combination with the PROFIBUS DP device support, the module provides a very powerful interface to the many Modbus TCP/IP devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
The PROFIBUS DP Slave driver gives access to the ProLinx unit's internal database via 244 bytes of Input data and 244 bytes of Output data (maximum 400 bytes total). These Input and Output data blocks are mapped by the user within the ProLinx module's data memory allowing the user maximum flexibility and data transfer with other protocols.
General Parameters |
|
GSD File |
PRLX05A5.GSD |
PROFIBUS Specifications |
|
Communication parameters | Baud Rate: 9.6 kbit/s – 12 Mbit/s |
Supported I/O length |
244 bytes Input data |
Supported PROFIBUS DP features |
PROFIBUS V0 Slave using Siemens SPC3 chipset |
Configurable Parameters |
PROFIBUS Node Address: 1 to 125 |
The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Specification | Description |
Power Supply |
24 VDC nominal |
Current Load | 500 mA max @ 32 VDC max |
Operating Temperature | -4° F to 122° F (-20° C to 50° C) |
Storage Temperature | -40° F to 185° F (-40° C to 85° C) |
Relative Humidity | 5% to 95% (with no condensation ) |
Dimensions |
Standard: |
LED Indicators |
Power and Module Status |
Configuration Serial Port |
DB-9M RS-232 only |
Ethernet Port (Ethernet modules only) | RJ45 Connector Link and Activity LED indicators |
Application Serial Ports |
RS-232/422/485 |
Serial Port Isolation |
2500V RMS port signal isolation per UL 1577 |
Shipped with Each Unit |
Mini-DIN to DB-9M serial cables |
The PROFIBUS DP Slave protocol driver supports the PROFIBUS V0 Slave implementation, providing powerful data transfer capability between the ProLinx module and Siemens PLCs or other hosts. User configurable data mapping and DP port operation make the interface an easy to use and powerful data transfer tool.
The PROFIBUS DP Slave driver gives access to the ProLinx unit's internal database via 244 bytes of Input data and 244 bytes of Output data (maximum 400 bytes total). These Input and Output data blocks are mapped by the user within the ProLinx module's data memory allowing the user maximum flexibility and data transfer with other protocols.
General Parameters |
|
GSD File | PRLX05A5.GSD Downloadable from ProSoft Technology web site |
PROFIBUS Specifications |
|
Communication parameters | Baud Rate: 9.6 kbps to 12 Mbps |
Supported I/O length | 244 bytes Input data 244 bytes Output data 400 bytes total |
Supported PROFIBUS DP features | PROFIBUS V0 Slave using Siemens SPC3 chipset Freeze Mode Sync Mode Auto Baud Setting |
Configurable Parameters | PROFIBUS Node Address: 1 to 125 Data byte swapping Action on loss of PROFIBUS connection Comm Fail Timeout Multiplier Status Data location in Internal Database |
The Modbus TCP/IP protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNET driver supports Client and Server connections, and when coupled with the Web option provides a web/ftp interface as well.
The Modbus TCP/IP driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP and other networks and devices.
Modbus TCP/IP Server |
|
General | Server supports up to 5 independent connections each to Modbus TCP/IP clients on Service Port 502 using the standard MBAP protocol, and Service Port 2000. |
Configurable Parameters |
Module IP Address |
Modbus TCP/IP Client |
|
General | Actively reads and writes data with Modbus TCP/IP compatible devices. One client connection (up to 100 servers/devices with 100 commands) |
Configurable parameters | Number of active commands, Min Command Delay, Response Timeout, Retry Count, Command Error Pointer |
Command List | Up to 100 fully configurable commands on the Client port |
Ex Certificate (ATEX Directive) | 114,27 kB | Zuletzt geändert 13.03.2019 |
CB Safety | 35,78 kB | Zuletzt geändert 27.08.2012 |
Declaration of Conformity (RoHS/CE) | 299,91 kB | Zuletzt geändert 04.03.2018 |
Country Approval - Eurasian Customs Union Conformity (EAC) (Wired) | 1,92 MB | Zuletzt geändert 10.07.2020 |
Country Approval - Eurasian Customs Union Conformity (EAC) (Wired) | 1,92 MB | Zuletzt geändert 10.07.2020 |
Korean KC Registration | 851,60 kB | Zuletzt geändert 13.03.2020 |
UL/cUL; Class 1, Div 2 | 1,08 MB | Zuletzt geändert 31.03.2020 |
UL/cUL; Class 1, Div 2 (Canada) | 1,10 MB | Zuletzt geändert 02.07.2013 |