      PLX51-DLPlus-232

      Data Logger Plus

      PLX51-DLplus-232

      The PLX51-DLplus-232 Data Logger is ideal for remote sites with limited communications that need to log data. OEMs can log their machine’s data to identify operational problems or efficiency improvements and can view this data online as trends via an integrated webserver. The trend data can be exported as a CSV file. The module supports REST API to collect JSON encoded data from the module that can be sent to other systems.

      The PLX51-DLplus-232 can read and store data from EtherNet/IP™ PLCs, DF1 Serial PLCs and devices, or Modbus® PLCs and devices. The PLX51-DLplus-232 has the capacity to store over 16 million records in its solid-state non-volatile memory. Each stored record includes a Date Time stamp, Tag Name, Data Type, and Value.

      Learn more about ProSoft’s Remote Connectivity Solutions.

      • Abbildungen
      • Funktionen und Vorteile
      • Technische Daten
      • Hardware-Spezifikationen
      • Downloads
      • Videos
      • Zertifikate

      Abbildungen

      Click on image(s) to enlarge
      Drag with the mouse. Click for close.

      Funktionen und Vorteile

      • A built in web server to trend up to five (5) user defined variables with configurable time period
      • REST API to collect JSON-encoded data and send to other systems
      • Stored data can be downloaded to a CSV file via the webserver or manually using the PLX50 Configuration Utility
      • A built-in webserver provides detailed diagnostics of system configuration and operation
      • Two logging modes: Data stored until memory is full or oldest data overwritten when memory is full - First in, First out

      Technische Daten

      EtherNet/IP

      Description

      Connector

      RJ45

      Conductors

      CAT5 STP/UTP

      ARP Connections

      Max 20

      TCP Connections

      Max 20

      CIP Connections

      Max 10

      Communication Rate

      10/100 Mbps

      Duplex Mode

      Full / Half

      Auto MDIX

      Yes

       

       

      Serial Port

      Description

      Baud Rate

      1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200

      Parity

      None, Even, Odd

      Data Bits

      8

      Stop Bits

      1

      RS232 Connector

      4-way terminal

      RS232 Conductor

      24 to 18 AWG

      RS232 Isolation Voltage

      2.5 kV

       

       

      DF1

      Description

      Protocol

      DF1 Full Duplex, DF1 Half Duplex

      Error Detection

      CRC, BCC

      Embedded Response

      Auto, On

       

       

      Modbus

      Description

      Protocol

      Modbus RTU, Modbus TCP/IP

      Function Codes Supported

      1: Read Coils

      2: Read Discrete Inputs

      3: Read Holding Registers

      4: Read Input Registers

       

       

      Data Logging

      Description

      Max Record Count

      16,777,216

      Max Tag Count

      200

      Log Criteria Supported

      Delta Change, Heartbeat, Tag Triggers

      Min Log Interval

      50 ms

      Data Types Supported

      BOOL, SINT, INT, DINT REAL

      Cached Records (Non-Volatile)

      Yes

      Log Triggers Supported

      Yes

      Data Sources

      Logix Tags, DF1 File, Modbus (RTU and TCP/IP)

       

       

      Data Trends Report

      Description

      Max Objects

      5

      Max number of records

      10,000 per object

      Upload to CSV

      Yes, up to 1,000,000 records per object

      Configure Tags

      Yes

      Configure Scaling

      Yes

       

       

      REST API Support

      Description

      JSON-encoded messages

      Yes

      Hardware-Spezifikationen

      Hardware Specifications

      Specification

      Description

      Enclosure

      Plastic

      Enclosure Rating

      IP20, NEMA/UL Open Type

      Dimensions (H x W x D)

      101.0 x 22.5 x 120.0 mm

      Power Requirements

      Input: 10 to 28 VDC, (70 mA @ 24 VDC / 130 mA @ 10 VDC)

      Power Consumption

      1.7 W

      Power Connector

      3-way terminal

      Conductors

      24 to 18 AWG

      Enclosure Rating

      IP20, NEMA / UL Open Type

      Temperature

      -20°C to 70°C

      Earth Connection

      Yes, terminal based

      Emissions

      IEC61000-6-4

      ESD Immunity

      EN 61000-4-2

      Radiated RF Immunity

      IEC 61000-4-3

      EFT/B Immunity

      EFT: IEC 61000-4-4

      Surge Immunity

      Surge: IEC 61000-4-5

      Conducted RF Immunity

      IEC 61000-4-6

      Downloads

      PLX51-DLplus-232 Datasheet 313,81 kB Zuletzt geändert 09.12.2022
      PLX51-DLplus-232 User Manual 2,90 MB Zuletzt geändert 06.01.2026
      PLX51-DLplus-232 Quick Start Guide 234,76 kB Zuletzt geändert 08.11.2024
      PLX51-DLPlus-232 Release Notes 303,28 kB Zuletzt geändert 12.01.2026
      PLX51-DLplus-232 Firmware v1.003.012 203,90 kB Zuletzt geändert 08.08.2022
      PLX51-DLplus-232 Sample Ladder 285,05 kB Zuletzt geändert 15.01.2021
      PLX51-DLplus-232 Sample Python v2.0 11,24 kB Zuletzt geändert 10.02.2023
      PLX51-DLplus-232 EDS Files 2,66 kB Zuletzt geändert 15.01.2021
      PLX51-DLplus-232 FAQ 150,40 kB Zuletzt geändert 15.01.2021
      PLX51-DLplus-232 Dimensional Drawing 968,84 kB Zuletzt geändert 22.06.2020
      ProSoft PLX50 Configuration Utility

      Videos

      Set Up: Log Data from Your Logix Controller

      Zertifikate

      ATEX Letter of Conformity 101,57 kB Zuletzt geändert 12.05.2022
      CB Safety 340,56 kB Zuletzt geändert 04.09.2019
      Declaration of Conformity (RoHS/CE) 139,57 kB Zuletzt geändert 16.11.2022
      ODVA EtherNet/IP Declaration of Conformity 135,16 kB Zuletzt geändert 15.10.2020
      UL/cUL; Class1, Div 2 236,84 kB Zuletzt geändert 04.09.2019
      Country Approval - Eurasian Customs Union Conformity (EAC) (Wired) 1,92 MB Zuletzt geändert 11.02.2022
      Declaration of REACH Compliance 390,10 kB Zuletzt geändert 17.06.2026
      Korean KC Registration 282,43 kB Zuletzt geändert 28.04.2022

Solutions

  • Amusement
  • Automated Material Handling
  • Automotive
  • IIoT Solutions
  • Mining and Metals
  • Modernization
  • Oil and Gas Solutions
  • Secure Remote Connectivity
  • Water & Wastewater

Produkte

  • Fernzugriff
  • Rockwell Automation In-chassis
  • Gateways
  • Industrial Wireless
  • ProSoft-Software

Service & Support

  • Knowledge Base
  • Regionaler technischer Support
  • Legacy Downloads
  • Training
  • $(document).ready(function(){ $('.popup-youtube, .popup-vimeo, .popup-gmaps').magnificPopup({ disableOn: 700, type: 'iframe', mainClass: 'mfp-fade', removalDelay: 160, preloader: false, fixedContentPos: false }); //pagelayout banner? if($('.banner-image') !== 'undefined' ){ var banner_image_src = $('.banner-image img').attr('src'); $('.banner-image').hide(); $('.banner-page-title').css('background-image', 'url(' + banner_image_src + ')'); $('.banner-page-title').css('background-repeat', 'no-repeat'); } //if( $('.analytics-file-download' ) !== 'undefined' ) { // $('.analytics-file-download' ).click(function(){ // var action = $( this ).attr( 'href' ); // var label = $( this ).attr( '_gaq-label' ); // var category = $( this ).attr( '_gaq-category' ); // return ga('send', 'event', category, action, label); // }); //} //initialize search? $("#div_search_field input").focusin(function(){ $(this).css("color", "#000000"); }); var initialSearch = $('form.search input.text').attr("value"); var currentSearch = ""; $('form.search input.text').focusin(function(){ currentSearch = $('form.search input.text').attr("value"); if( currentSearch == initialSearch ) { $('form.search input.text').attr("value",""); } }); }); //Homepage slideshow if( $('#slider') !== 'undefined' ) { $('#slider').nivoSlider({ pauseTime: 7000 // time for a slide to show, in milliseconds; subtract 2 seconds for actual time due to transition time }); } //eZ Live Viewer //(function(){var ff=document.createElement('script');ff.type='text/javascript';ff.async=true;ff.src=('https:'==document.location.protocol?'https':'http')+'://liveviewer.ez.no/statjs/sst-118-973155090/stat.js';var s=document.getElementsByTagName('script')[0];s.parentNode.insertBefore(ff,s);})(); // Pardot integration piAId = '281892'; piCId = '1546'; (function() { function async_load(){ var s = document.createElement('script'); s.type = 'text/javascript'; s.src = ('https:' == document.location.protocol ? 'https://pi' : 'http://cdn') + '.pardot.com/pd.js'; var c = document.getElementsByTagName('script')[0]; c.parentNode.insertBefore(s, c); } if(window.attachEvent) { window.attachEvent('onload', async_load); } else { window.addEventListener('load', async_load, false); } })();