Automating integration for Schneider Electric (SE) Modicon processors and maximizing ease-of-use are the hallmark design criteria behind the new ProLinx SE line of communication gateways. The first SE gateway, the 5204SE-MNET-PDPMV1 Modbus TCP/IP to PROFIBUS DP-V1 Master gateway, easily turns a Modicon M340 or a Quantum Programmable Automation Controller (PAC) into a PROFIBUS DP-V1 Master. The new Application Communication Logic functions built into ProSoft Configuration Builder (PCB) automatically generate all the Unity Pro data types, variables, and logic required for the M340 or Quantum to perform PROFIBUS DP-V1 cyclic and acyclic communication.
PCB automatically generates customized export files based on the PROFIBUS DP network configuration for the gateway. These files import into Unity Pro version 4 software without modification, eliminating the need to write additional communications message logic.
Automatically-generated Derived Function Block logic also provides advanced PROFIBUS DP-V1 acyclic message pass-through capability. Acyclic messaging allows an M340 or Quantum to request extended slave data and diagnostics, as well as access slave-specific special functions.
Whenever the PROFIBUS DP network configuration changes, new logic files can be automatically created, exported, and imported into an existing project, reducing engineering demands and cutting deployment time. Changes to gateway configuration can be password-protected.
The Modbus TCP/IP (MNET) driver can be used to interface many different protocols into the Schneider Electric Quantum family of processors as well other software solutions supporting the protocol. The MNET driver supports Client connections as well as Server connections.
The PROFIBUS DP Master protocol driver (PDPMV1) supports complete Master specifications according to IEC 61158 on either a Mono-Master or Multi-Master network. The module supports the DPV1 specification.
New Application Communication Logic functions for use with Modicon M340 or Quantum PACs |
|
Acyclic Pass-Through Capability |
|
Backed by ProSoft Technology |
|
The ProLinx Communication Modules provide connectivity for two or more dissimilar network types. The modules, encased in sturdy extruded aluminum, are stand-alone DIN-rail mounted protocol gateways, providing communication between many of the most widely used protocols in industrial automation today.
Specification | Description |
Power Supply |
24 VDC nominal |
Current Load | 500 mA max @ 32 VDC max |
Operating Temperature | -4° F to 122° F (-20° C to 50° C) |
Storage Temperature | -40° F to 185° F (-40° C to 85° C) |
Relative Humidity | 5% to 95% (with no condensation ) |
Dimensions |
Standard: |
LED Indicators |
Power and Module Status |
Configuration Serial Port |
DB-9M RS-232 only |
Ethernet Port (Ethernet modules only) |
10Base-T half duplex RJ45 Connector |
Application Ports |
Modbus Plus Connector |
Serial Port Isolation |
2500 V RMS port signal isolation per UL 1577 |
Shipped with Each Unit |
Mini-DIN to DB-9M serial cables |
ProSoft Configuration Builder (PCB) | ||
5204SE-MNET-PDPMV1Datasheet | 574,40 kB | Zuletzt geändert 10.05.2010 |
MNET Protocol Manual | 631,11 kB | Zuletzt geändert 16.02.2012 |
PDPMV1 Protocol Manual | 3,04 MB | Zuletzt geändert 08.02.2017 |
SE MNET-PDPMV1 User Manual | 3,78 MB | Zuletzt geändert 10.05.2010 |
The module supports complete Master specifications according to IEC 61158. Acyclic parameter data can be transferred with Class 1 or Class 2 DPV1 services, allowing processors to easily communicate with slave devices supporting PROFIBUS DPV0/V1 protocol.
The ProLinx PDPMV1 PROFIBUS Master module acts as a PROFIBUS network scanner, transferring Input and Output data between PROFIBUS devices and the network.
PROFIBUS Master Specifications
PROFIBUS Master Port
The PROFIBUS DP Master protocol driver supports complete Master specifications according to IEC 61158 on either a Mono-Master or Multi-Master network. The module supports the DPV1 specification.
The Modbus TCP/IP protocol driver can interface many different protocols into Schneider Electric Quantum processors as well other solutions supporting the protocol. The MNET driver supports Client and Server connections, and when coupled with the Web option provides a web/ftp interface as well.
The Modbus TCP/IP driver interfaces with a common internal database in the module. This permits the sharing of data between the Modbus TCP/IP and other networks and devices.
Modbus TCP/IP Server |
|
General | Server supports up to 5 independent connections each to Modbus TCP/IP clients on Service Port 502 using the standard MBAP protocol, and Service Port 2000. |
Configurable Parameters |
Module IP Address |
Modbus TCP/IP Client |
|
General | Actively reads and writes data with Modbus TCP/IP compatible devices. One client connection (up to 100 servers/devices with 100 commands) |
Configurable parameters | Number of active commands, Min Command Delay, Response Timeout, Retry Count, Command Error Pointer |
Command List | Up to 100 fully configurable commands on the Client port |
Ex Certificate (ATEX Directive) | 114,27 kB | Zuletzt geändert 13.03.2019 |
CB Safety | 35,78 kB | Zuletzt geändert 27.08.2012 |
Declaration of Conformity (RoHS/CE) | 300,09 kB | Zuletzt geändert 04.03.2018 |
Russian GOST-R | 7,07 MB | Zuletzt geändert 22.02.2013 |
GOST-R Declaration of Conformity | 6,68 MB | Zuletzt geändert 22.02.2013 |
UL/cUL; Class 1, Div 2 | 1,08 MB | Zuletzt geändert 02.07.2013 |
UL/cUL; Class 1, Div 2 (Canada) | 1,10 MB | Zuletzt geändert 02.07.2013 |