      MVI56E-SMGC

      FMC722 TPU General Communication Module

      MVI56E-SMGC

      The MVI56E-SMGC FMC722 TPU General Communication Module allows Rockwell Automation® ControlLogix® compatible processors to interface easily with FMC722 TPU General Communication Protocol devices over an Ethernet network.

      The MVI56E-SMGC module interfaces an Ethernet communication device using the FMC722 TPU General Communication Protocol with the Rockwell Automation ControlLogix processor. A single client is present in the module to interface with a single server. The client permits both the reception and transmission of data between the Rockwell Automation processor and attached device.

      • Funktionen und Vorteile
      • Hardware-Spezifikationen
      • Downloads
      • Videos
      • Zertifikate

      Funktionen und Vorteile

      • Single Slot – 1756 backplane compatible
      • The module is recognized as an Input/Output module and has access to processor memory for data transfer between processor and module
      • Ladder Logic is used for data transfer between module and processor. Sample ladder file included
      • The module is configurable through the ProSoft Configuration Builder software
      • Local or remote rack

      Hardware-Spezifikationen

      Specification

      Description

      Backplane Current Load

      800 mA @ 5 VDC
      3 mA @ 24 VDC

      Operating Temperature

      0°C to 60°C (32°F to 140°F)

      Storage Temperature

      -40°C to 85°C (-40°F to 185°F)

      Shock

      30 g operational
      50 g non-operational
      Vibration: 5 g from 10 Hz to 150 Hz

      Relative Humidity

      5% to 95% RH, with no condensation

      LED Indicators

      ERR (Reserved)
      APP (Application Status)
      OK (Module Status)

      4-Character, Scrolling, Alpha-Numeric LED Display

      Shows Module, IP and Port Status

      Ethernet Port (E1)

      10/100 Base-T, RJ45 Connector, for CAT5 cable
      Link and Activity LED indicators
      Auto-crossover cable detection

      Downloads

      MVI56E-SMGC Datasheet 344,68 kB Zuletzt geändert 09.12.2022
      MVI56E-SMGC User Manual 2,99 MB Zuletzt geändert 23.11.2023
      MVI56E-SMGC Sample Ladder 136,54 kB Zuletzt geändert 07.09.2021
      ProSoft Configuration Builder
      MVI56E CAD Drawings (STEP) 11,16 MB Zuletzt geändert 15.09.2023
      LifeCycle Letter MVI56E Series 150,72 kB Zuletzt geändert 01.04.2026

      Videos

      Data Organization in ProSoft Modules and Gateways

      Guide to bit-level data addressing in ProSoft Modbus modules

      Guide to 32-bit data types in ProSoft Modbus modules

      Zertifikate

      ATEX Letter of Conformity 101,65 kB Zuletzt geändert 12.05.2022
      Country Approval - Australia 185,51 kB Zuletzt geändert 31.08.2021
      CB Safety 504,75 kB Zuletzt geändert 06.10.2021
      Declaration of Conformity (RoHS/CE) 136,60 kB Zuletzt geändert 20.01.2023
      Declaration of REACH Compliance 388,80 kB Zuletzt geändert 18.12.2025
      UL/cUL; Class 1, Div. 2 190,81 kB Zuletzt geändert 31.08.2021
      Country Approval - Eurasian Customs Union Conformity (EAC) (Wired) 1,92 MB Zuletzt geändert 10.07.2020

Solutions

  • Amusement
  • Automated Material Handling
  • Automotive
  • IIoT Solutions
  • Mining and Metals
  • Modernization
  • Oil and Gas Solutions
  • Secure Remote Connectivity
  • Water & Wastewater
$(document).ready(function(){ $('.popup-youtube, .popup-vimeo, .popup-gmaps').magnificPopup({ disableOn: 700, type: 'iframe', mainClass: 'mfp-fade', removalDelay: 160, preloader: false, fixedContentPos: false }); //pagelayout banner? if($('.banner-image') !== 'undefined' ){ var banner_image_src = $('.banner-image img').attr('src'); $('.banner-image').hide(); $('.banner-page-title').css('background-image', 'url(' + banner_image_src + ')'); $('.banner-page-title').css('background-repeat', 'no-repeat'); } //if( $('.analytics-file-download' ) !== 'undefined' ) { // $('.analytics-file-download' ).click(function(){ // var action = $( this ).attr( 'href' ); // var label = $( this ).attr( '_gaq-label' ); // var category = $( this ).attr( '_gaq-category' ); // return ga('send', 'event', category, action, label); // }); //} //initialize search? $("#div_search_field input").focusin(function(){ $(this).css("color", "#000000"); }); var initialSearch = $('form.search input.text').attr("value"); var currentSearch = ""; $('form.search input.text').focusin(function(){ currentSearch = $('form.search input.text').attr("value"); if( currentSearch == initialSearch ) { $('form.search input.text').attr("value",""); } }); }); //Homepage slideshow if( $('#slider') !== 'undefined' ) { $('#slider').nivoSlider({ pauseTime: 7000 // time for a slide to show, in milliseconds; subtract 2 seconds for actual time due to transition time }); } //eZ Live Viewer //(function(){var ff=document.createElement('script');ff.type='text/javascript';ff.async=true;ff.src=('https:'==document.location.protocol?'https':'http')+'://liveviewer.ez.no/statjs/sst-118-973155090/stat.js';var s=document.getElementsByTagName('script')[0];s.parentNode.insertBefore(ff,s);})(); // Pardot integration piAId = '281892'; piCId = '1546'; (function() { function async_load(){ var s = document.createElement('script'); s.type = 'text/javascript'; s.src = ('https:' == document.location.protocol ? 'https://pi' : 'http://cdn') + '.pardot.com/pd.js'; var c = document.getElementsByTagName('script')[0]; c.parentNode.insertBefore(s, c); } if(window.attachEvent) { window.attachEvent('onload', async_load); } else { window.addEventListener('load', async_load, false); } })();