• English
  • 中文
  • Français
  • Deutsch
  • Español
Contact Us
Home
Email
Follow Prosoft Technology on Twitter
Follow Prosoft Technology on Facebook
Follow Prosoft Technology on LinkedIn
Follow Prosoft Technology on YouTube
    • PROFINET Controller Module for ControlLogix®
    • EtherNet/IP™ to DH+ Gateway
    • Two-Port Building Automation Gateway
  • Solutions
    • Amusement
    • Automated Material Handling
    • Automotive
    • IIoT Solutions
    • Products for Rockwell Automation Platforms

      Produkte

      • Fernzugriff
      • Rockwell Automation In-chassis
      • Gateways
      • Industrial Wireless
      • ProSoft-Software
      Rockwell Automation In-chassis  >  PROFIBUS DPV1 Master/Slave for ControlLogix
      Find a Distributor Request Pricing
      ILX56-PBM Product Photo - ControlLogix PROFIBUS Master Module

      PROFIBUS DPV1 Master/Slave for ControlLogix®

      ILX56-PBM

      The ILX56-PBM PROFIBUS DPV1 Master/Multi-Slave module allows Rockwell Automation® ControlLogix® processors to communicate with various PLCs and devices using the PROFIBUS DP protocol.  As a PROFIBUS DP Master, the module can transfer up to 5000 bytes of cyclic I/O data with various slave devices on the network. 

      Or you can use the module as a PROFIBUS DP multi-slave, where the module can emulate up to 10 individual nodes on a PROFIBUS DP network, allowing for more cyclic I/O data transfer. 

      With the ILX56-PBM module, ControlLogix® processors can easily communicate with devices supporting PROFIBUS DPV0 and DPV1 protocol. And through premier integration tools such as a custom Add-On Profile, project-specific Add-On Routines, and advanced tools such as PROFIBUS DP packet capture utility, you can minimize the time required to get a PROFIBUS DP network configured in a ControlLogix® environment.

      In addition, with the use of multiple I/O connections back to the ControlLogix® processor, this module provides data update rates that will meet even the most demanding applications.   

      • Abbildungen
      • Funktionen und Vorteile
      • Technische Daten
      • Hardware-Spezifikationen
      • Downloads
      • Videos
      • Zertifikate

      Abbildungen

      Click on image(s) to enlarge
      Drag with the mouse. Click for close.
      Drag with the mouse. Click for close.

      Funktionen und Vorteile

      • AOP and AOI: Module communication is integrated within Studio/RSLogix™ 5000 using a sample Add-On Instruction (AOI), and custom configuration utility created Add-On Routines to reduce commissioning time.
      • Autoscan: The Autoscan feature reduces startup times and simplifies troubleshooting by scanning the PROFIBUS network and uploading slave device addresses and configuration information. (Reads and maps nodes automatically to the module.)
      • ComDTM: Allows remote Ethernet connectivity with Asset Management Software, significantly lowering maintenance costs. You can configure, commission, maintain and diagnose your fieldbus devices throughout their entire lifecycle with this comprehensive, fully integrated engineering and maintenance environment.
      • SD card slot (SD card optional) is used for storing configuration files in the event of a disaster.
      • Redundancy: Two modules can be used along with the custom Add-On Routine to allow for a redundant PROFIBUS DP network for high availability systems.

      Technische Daten

      PROFIBUS DP Master Specifications

      Specification

      Description

      Slaves

      Maximum 125

      Input/Output

      Maximum 244 Bytes per Slave

      Input Data

      Maximum 5000 Bytes

      Acyclic Data

      DPV1

      Status data

      88 Bytes

      Output data

      Maximum 5000 Bytes

      DPV1 Services

      Class 1 Read/Write
       Class 1 Alarm
       Class 2 Initiate/Read/Write/Abort

      Services

      Global-Control, Slave-Diagnostic, Set-Parameter

      Sync, Freeze Command

      Supported

      Baud rate

      9.6 kBaud, 19.2 kBaud, 45.45 kBaud, 93.75 kBaud, 187.5 kBaud, 500 kBaud 1.5 MBaud, 3 MBaud, 6 MBaud, 12 MBaud

       

       

      PROFIBUS DP Slave Specifications

      Specification

      Description

      Slaves

      Emulate up to 10 slaves

      Input/Output

      Maximum 244 Bytes per Slave

      Input Data

      Maximum 2440 Bytes

      Acyclic Data

      DPV1

      Status data

      88 Bytes

      Output data

      Maximum 2440 Bytes

      DPV1 Services

      Class 1 Read/Write, Class 1 Alarm            

      Services

      Global-Control, Slave-Diagnostic, Set-Parameter

      Sync, Freeze Command

      Supported

      Baud rate

      9.6 kBaud, 19.2 kBaud, 45.45 kBaud, 93.75 kBaud, 187.5 kBaud, 500 kBaud 1.5 MBaud, 3 MBaud, 6 MBaud, 12 MBaud. Auto-detection mode is supported

      Hardware-Spezifikationen

       

      Specification

      Description

      PROFIBUS Interface

      RS-485, Max. 12 Mbps, potential free, according EN 50170

      Power Supply

      450 mA @ 5Vdc, 2 mA @ 24 Vdc

      Dimensions

      Standard 1756 Single-slot module

      Burst

      EN 61000-4-4, 2 kV, 5 kHz

      Surge

      EN 61000-4-5, 2 kV common mode, 1 kV differential mode

      ESD

      EN 61000-4-2, 4 kV contact, 8 kV air, 4 kV indirect

      Radiated/Conducted Immunity

      EN 61000-4-3, 10 V/m, 30...1000 MHz, 80% AM, 1 kHz sine wave
       EN 61000-4-6, 10 V, 0,15...80 MHz

      Radiated/Conducted Emission

      EN 55011 Class A

      Vibration/Shock (operating)

      IEC 600068-2-6, 10-500 Hz, ± 0,75 mm, ± 2 g, 1 Octave/min IEC 600068-2-27, 30 g, 11 ms

      Operating Temperature

      0°C  to 60°C (32°F to 140°F)

      Relative Humidity

      5 to 95% (non-condensing)

      Downloads

      ILX56-PBM Datasheet 414,38 kB Zuletzt geändert 09.12.2022
      ILX56-PBM User Manual 4,51 MB Zuletzt geändert 30.10.2025
      ILX56-PBM GSD file 3,60 kB Zuletzt geändert 18.05.2020
      ILX56-PBM EDS Files 2,54 kB Zuletzt geändert 04.11.2024
      ILX56-PBM Firmware v1.001.016 191,27 kB Zuletzt geändert 25.03.2026
      ILX56-PBM Release Notes 290,77 kB Zuletzt geändert 18.02.2026
      ILX56-PBM Add-On Instruction 16,59 kB Zuletzt geändert 17.12.2024
      ILX56-PBM / ILX56-PBS AOP Files 493,35 kB Zuletzt geändert 23.04.2025
      ILX56-PBx CAD Drawings (STEP) 7,45 MB Zuletzt geändert 15.09.2023
      Technical Note - ILX56-PBM Installing Logix v20 and below 716,47 kB Zuletzt geändert 17.12.2024
      PLX51 ILX56 HART and PROFIBUS - DTM Pack Configuration Software v1.008 4,51 MB Zuletzt geändert 03.04.2020
      ProSoft PLX50 Configuration Utility
      LifeCycle Letter ILX56-PBx 111,07 kB Zuletzt geändert 10.04.2025

      Videos

      Set Up: PROFIBUS DPV1 Master/Slave Module for ControlLogix®

      Zertifikate

      ATEX Letter of Conformity 101,65 kB Zuletzt geändert 09.01.2025
      CB Safety 335,02 kB Zuletzt geändert 04.03.2025
      Declaration of Conformity (RoHS/CE) 547,35 kB Zuletzt geändert 09.01.2025
      UL/cUL; Class 1, Div. 2 84,59 kB Zuletzt geändert 09.01.2025
      Declaration of REACH Compliance 396,54 kB Zuletzt geändert 18.12.2025
      Country Approval - Korea - KC Registration 281,11 kB Zuletzt geändert 18.03.2022
      Country Approval - Eurasian Customs Union Conformity (EAC) (Wired) 1,92 MB Zuletzt geändert 10.07.2020

Solutions

  • Amusement
  • Automated Material Handling
  • Automotive
  • IIoT Solutions
  • Mining and Metals
  • Modernization
  • Oil and Gas Solutions
  • Secure Remote Connectivity
  • Water & Wastewater
$(document).ready(function(){ $('.popup-youtube, .popup-vimeo, .popup-gmaps').magnificPopup({ disableOn: 700, type: 'iframe', mainClass: 'mfp-fade', removalDelay: 160, preloader: false, fixedContentPos: false }); //pagelayout banner? if($('.banner-image') !== 'undefined' ){ var banner_image_src = $('.banner-image img').attr('src'); $('.banner-image').hide(); $('.banner-page-title').css('background-image', 'url(' + banner_image_src + ')'); $('.banner-page-title').css('background-repeat', 'no-repeat'); } //if( $('.analytics-file-download' ) !== 'undefined' ) { // $('.analytics-file-download' ).click(function(){ // var action = $( this ).attr( 'href' ); // var label = $( this ).attr( '_gaq-label' ); // var category = $( this ).attr( '_gaq-category' ); // return ga('send', 'event', category, action, label); // }); //} //initialize search? $("#div_search_field input").focusin(function(){ $(this).css("color", "#000000"); }); var initialSearch = $('form.search input.text').attr("value"); var currentSearch = ""; $('form.search input.text').focusin(function(){ currentSearch = $('form.search input.text').attr("value"); if( currentSearch == initialSearch ) { $('form.search input.text').attr("value",""); } }); }); //Homepage slideshow if( $('#slider') !== 'undefined' ) { $('#slider').nivoSlider({ pauseTime: 7000 // time for a slide to show, in milliseconds; subtract 2 seconds for actual time due to transition time }); } //eZ Live Viewer //(function(){var ff=document.createElement('script');ff.type='text/javascript';ff.async=true;ff.src=('https:'==document.location.protocol?'https':'http')+'://liveviewer.ez.no/statjs/sst-118-973155090/stat.js';var s=document.getElementsByTagName('script')[0];s.parentNode.insertBefore(ff,s);})(); // Pardot integration piAId = '281892'; piCId = '1546'; (function() { function async_load(){ var s = document.createElement('script'); s.type = 'text/javascript'; s.src = ('https:' == document.location.protocol ? 'https://pi' : 'http://cdn') + '.pardot.com/pd.js'; var c = document.getElementsByTagName('script')[0]; c.parentNode.insertBefore(s, c); } if(window.attachEvent) { window.attachEvent('onload', async_load); } else { window.addEventListener('load', async_load, false); } })();