AN-X-PB,PROFIBUS Multi-Slave or PROFIBUS Network Analyzer Gateway

PROFIBUS Multi-Slave or PROFIBUS Network Analyzer Gateway, non-CE

AN-X-PB

The PROFIBUS Multi-Slave or PROFIBUS Network Analyzer Gateway has two distinct operational modes.  The first mode, PROFIBUS Multi-Slave, enables the transfer of large amounts of data from a PROFIBUS DP Master controller to EtherNet/IP and/or Modbus TCP-enabled PLCs.  The Multi-Slave functionality allows up to 15,250 words of Input and Output data to be transferred without requiring multiplexing PLC code to be written in a traditional single slave solution. The second mode, PROFIBUS Network Capture, facilitates the capture, logging, and filtering of packets on a PROFIBUS network without interrupting the running production network.  This enables a root cause analysis to be performed on the captured PROFIBUS packets which aids in the identification of complex issue(s). 

Abbildungen

Click on image(s) to enlarge
Drag with the mouse. Click for close.

Technische Daten

PROFIBUS Multi-Slave Features:    

  • Configures through a web browser (No special configuration software required)
  • Configuration option of 1 to 125 PROFIBUS slaves
  • Supports PROFIBUS Baud Rates of 9600 bps - 12 Mbps
  • PROFIBUS Network monitoring tool shows network traffic to and from a user specified node address
  • Ability to view configuration and diagnostics through a web browser enabling remote monitoring or troubleshooting
  • Supports sending up to 250 words of input data, and 248 words of output data on an I/O connection to an Allen-Bradley PLC
  • Supports Class 3 message instructions to move data to Allen-Bradley PLCs
  • Supports up to 16 Modbus TCP client connections
  • Supports Modbus Function Codes 2, 3, 4, 5, 6, 15, 16
 

PROFIBUS Capture Features:

  • Passively monitors all PROFIBUS packets sent across the network
  • Capture file can be configured to use a circular buffer, to capture data for a specific amount of time, or to stop capturing after a specified number of errors have occurred.
  • Filtering options include: Source Address, Destination Address, Frame Control Values, Detailed Status,
  • Frame Data, and Frame CheckSum which enables only the data specified to be logged and displayed
  • A filtering equation can be written to further limit the captured and displayed data
  • Customizable time format
  • Captured data can be saved for future use
  • Passively monitors all PROFIBUS packets sent across the network

Hardware

Specification

Description

Ports

1 RJ45 10/100 Mbps Ethernet port for EtherNet/IP™ connection

1 DB9 serial connector for the PROFIBUS network connection

1 Phoenix 3-pin power connector

Typical Power Consumption

300 mA @ 12 Vdc or 150 mA @ 24 Vdc

Maximum Power Dissapation

3.6W

Operating Temp

32°F to 122°F  (0 ºC  to 50 ºC)

Storage Temperature

-40°F to 185°F  (-40 ºC  to 85 ºC)

Dimensions

107 mm x 126 mm x 34 mm
 (4.18 in x 4.97 in x 1.33 in)
  not including connectors

Humidity

5% to 95% RH, with no condensation

Desktop use or DIN Rail Mountable

Downloads

AN-X-PB Datasheet 372,22 kB Zuletzt geändert 12.11.2018
AN-X-PB Capture User Manual 611,38 kB Zuletzt geändert 26.02.2013
AN-X-PB Capture Mode Files 2,74 MB Zuletzt geändert 05.09.2013
AN-X-PB Initialization Software 262,33 kB Zuletzt geändert 05.09.2013
AN-X-PB Slave User Manual 1,46 MB Zuletzt geändert 07.11.2013
AN-X-PB Slave Mode Files 4,62 MB Zuletzt geändert 05.09.2013