The A-CANBR/B CAN Bus Router provides intelligent data routing between either EtherNet/IP™ or Modbus® TCP/RTU and a CAN Bus network. This allows the user to integrate CAN Bus devices into a Rockwell Automation Logix platform (e.g., ControlLogix® or CompactLogix™) or any Modbus Client or Server device with minimal effort.

The A-CANBR/B also provides a range of statistics, CAN Bus and Modbus packet capture functions, and internal Modbus and Data table reads to simplify remote diagnosis. A built-in webserver provides detailed diagnostics of system configuration and operation, including the display of CAN Bus operation and communication statistics, without the need for any additional software.

Abbildungen

Click on image(s) to enlarge
Drag with the mouse. Click for close.
Drag with the mouse. Click for close.
Drag with the mouse. Click for close.

Funktionen und Vorteile

  • Receive up to 100 pre-configured CAN Bus packets.
  • Send up to 100 pre-configured CAN Bus packets.
  • CAN Bus transmission can be scheduled (periodic), or externally triggered, sent on Start-up, or any combination.
  • Logix L5X generation - Ready for import
  • Supports Passthrough Messaging from Logix
  • Module has various Primary Interfaces:
    • EtherNet/IP Target (Class 1 connection)
    • Modbus Server (TCP, RTU232, and RTU485)
    • Modbus Client (TCP, RTU232, and RTU485)
    • EtherNet/IP Originator (Class 1 connection with up to 10 EtherNet/IP devices and Explicit Messaging, including Direct-To-Tag Logix tag access, with up to 10 EtherNet/IP devices).
  • Slate software provides a CAN Bus and Modbus packet capture utility for better diagnosis of communication issues.
  • Supports common CAN Bus Baud Rates (10k, 20k, 50k, 125k, 250k, 500k, 800k, 1M)
  • Dual Ethernet ports which support Device-Level-Ring (DLR).
  • Network Time Protocol (NTP) supported for external time synchronization.
  • Small form factor – DIN rail mounted
  • The Slate Configuration Utility software is used for configuration and troubleshooting of the router. The stand-alone configuration utility allows users to define the setup and configuration of the CAN Bus router and its connections with controllers and devices. 

Technische Daten

Ethernet Ports

Specification

Rating

Connector

RJ45

Conductors

CAT5 STP/UTP

ARP Connections

Max 100

TCP Connections

Max 100

CIP Connections

Max 15

Communication Rate

10/100 Mbps

Duplex Mode

Full / Half

Auto-MDIX Support

Yes

Embedded Switch

Yes, 2x Ethernet ports

Device Level Ring (DLR)

Supported

Network Time Protocol (NTP)

Supported

Serial Port (RS232)

Specification

Rating

RS232 Connector

9-way terminal (shared with RS485)

RS232 Conductor

24 to 18 AWG

Electrical Isolation

1000 VDC

Baud Rate

1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200

Parity

None, Even, Odd

Data Bits

8

Stop Bits

1

 

Serial Port (RS485)

Specification

Rating

RS485 Connector

9-way terminal (shared with RS485)

RS485 Conductor

24 to 18 AWG

Electrical Isolation

1500 Vrms for 1 minute

Baud Rate

1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200

Parity

None, Even, Odd

Data Bits

8

Stop Bits

1

 

CAN BUS Network

Specification

Rating

Connector

5-way terminal, 5.08mm pitch.

Max CAN Receive Items

100

Max CAN Send Items

100

Passthrough Messaging

Supported

Supported Baud Rates

10k, 20k, 50k, 125k, 250k, 500k, 800k, 1M

CAN Terminator

120 Ω - Software Enabled

 

EtherNet/IP Target

Specification

Rating

Class 1 Cyclic connection count

4

Logix Direct-to-Tag Supported

Yes

 

EtherNet/IP Originator

Specification

Rating

Class 1 Cyclic Connections Supported

Yes

Class 3 / UCMM Connections Supported

Yes

Class 1 Connection Count

10

Class 3 / UCMM Target Device Count

10

Class 3 / UCMM Mapping Count

50

 

Modbus Client

Specification

Rating

Modes Supported

Modbus TCP, Modbus RTU232, Modbus RTU485

Modbus RTU485 Termination

125 Ω - Software Enabled

Max. Modbus Server Devices

20

Max. Modbus Mapping

100

Mapping Ranges

Holding Register 0 to 65535
Input Register 0 to 65535
Input Status 0 to 65535
Coil Status 0 to 65535

Base Offset

Modbus (Base 0)
PLC (Base 1)

Configurable Modbus TCP Port

Yes

Data Reformatting Supported

BB AA
BB AA DD CC
CC DD AA BB
DD CC BB AA

Modbus Server

Specification

Rating

Modes Supported

Modbus TCP, Modbus RTU232, Modbus RTU485 (simultaneous)

Modbus RTU485 Termination

Software set

Mapping Ranges

Holding Register 0 to 65535
Input Register 0 to 65535
Input Status 0 to 65535
Coil Status 0 to 65535

Base Offset

Modbus (Base 0)
PLC (Base 1)

Configurable Modbus TCP Port

Yes

Hardware-Spezifikationen

Specification

Rating

Power Supply

Input: 10 to 32 VDC

Power Consumption

2.2 W (Max.)
Current: 180 mA @ 10 V
Current: 85 mA @ 24 V

Dimensions (H x W x D)

149.0 x 34.0 x 116.0 mm (5.86 x 1.34 x 4.56 in)

Connector

3-way terminal

Conductors

24 to 18 AWG

Enclosure Rating

IP20, NEMA/UL Open Type

Temperature

-20°C to 70°C  (-4°F to 158°F )

Humidity

0 to 95% RH, non-condensing

Earth Connection

Yes, terminal based

Emissions

IEC 61000-6-4

ESD Immunity

EN 61000-4-2

Radiated RF Immunity

IEC 61000-4-3

EFT/B Immunity

EFT: IEC 61000-4-4

Surge Immunity

Surge: IEC 61000-4-5

Conducted RF Immunity

IEC 61000-4-6