The PS69 PROFIBUS DP Master module expands the functionality of ’s CompactLogix / MicroLogix family of processors to include PROFIBUS. This module supports both I/O control and messaging, thus integrating DPV0 and DPV1 functionality into CompactLogix / MicroLogix.

The PS69-DPM is a CompactLogix / MicroLogix compatible, PROFIBUS certified module, which enables controllers to communicate with a PROFIBUS network. The configuration and diagnostic of the PROFIBUS system is done via the serial diagnostic interface of the module using the System Configuration tool . The data exchange between controller and module is done via the I/O process data image using CompactLogix / MicroLogix backplane technology.

Abbildungen

Click on image(s) to enlarge
Drag with the mouse. Click for close.

Funktionen und Vorteile

PROFIBUS certified

Recognized quality certification mark

FDT configuration software and communication DTM included

Module DTM will configure master module and network slave devices. The DTM can be used in many FDT compatible software containers

Sample ladder program

Simplifies integration for quick and easy project start-up

Supports CIP ladder logic messaging

Request diagnostic, status and slave data based on ladder events. Offer better cyclic data performance

Anwendungen

Configuration

The configuration and diagnostic of the PROFIBUS system is done via the serial diagnostic interface of the module using the PROSOFT.fdt system configuration software tool. PROSOFT.fdt is FDT style configuration software and a communication DTM is included with the module allowing easy configuration of the PROFIBUS Master and network slave devices.

The master and network configuration are stored in the FLASH memory of the module.

The PS69-DPM interface appears to the Logix Controller as a standard I/O module and can be configured with RSLogix™ 5000 by Rockwell Automation®.

Technische Daten

Specification

Description

Slaves

Maximum 125

Input/Output

Maximum 244 Bytes per Slave

Input Data

Maximum 408 Bytes (*)

Acyclic Data

DPV1

Status data

88 Bytes

Output data

Maximum 480 Bytes (*)

Command data

16 Bytes

DPV1 services

Read / Write class 1, Alarm

Services

Global-Control, Slave-Diag, Set-Parameter

Sync, Freeze Command

Supported

Up to 32 PROFIBUS devices can be connected to one bus segment. If several bus segments are linked to each other with repeaters, there can be up to 127 devices on the network.

The maximum length of a bus segment depends on the baud rate used. Only PROFIBUS certified cable, preferably the cable type A, should be used.

Baud rate in kBit/s

Max. Distance

9.6

1,200 m / 4000 ft

19.2

1,200 m / 4000 ft

93.75

1,200 m / 4000 ft

187.5

1,000 m / 3280 ft

500

400 m / 1300 ft

1,500

200 m / 650 ft

3,000

100 m / 325 ft

6,000

100 m / 325 ft

12,000

100 m / 325 ft

Parameter

Value

Impedance

135 to 65 Ohm

Capacity

< 30 pF/m

Loop resistance

110 Ohm/km

Wire gauge

0.64 mm

  • Single Slot – 1769 backplane compatible
  • The module is recognized as an I/O module and the data exchange between controller and module is done via the I/O data image using CompactLogix / MicroLogix backplane technology.
  • Ladder logic is used for data transfer between module and processor. Sample ladder file included.
  • Supports CompactLogix processors and MicroLogix 1500 LRP

Hardware-Spezifikationen

Specification

Description

Processor

EC1-160P with integrated ASPC2

PROFIBUS Interface

RS-485, max. 12 Mbps, potential free, according EN 50170

Diagnostic Interface

RS-232, PS/2 Mini-DIN female connector, 9600 Baud, non isolated

Power Supply

260 mA at +5 V ±5 %

Power Supply Distance Rating

6
(no more than 6 modules away from the 1769 power supply)

Dimensions

Standard 1769 Single-slot module

Burst

EN 61000-4-4, 2 kV, 5 kHz

Surge

EN 61000-4-5, 2 kV common mode, 1 kV differential mode

ESD

EN 61000-4-2, 4 kV contact, 8 kV air, 4 kV indirect

Radiated/ Conducted Immunity

EN 61000-4-3, 10 V/m, 30 to 1000 MHz, 80% AM, 1 kHz sinewave

EN 61000-4-6, 10 V, 0.15 to 30 MHz

Radiated/ Conducted Emission

EN 55011 Class A

Vibration/Shock

IEC 600068-2-6, 10 to 150 Hz,
 ± 0.75 mm, ± 1 g, 1 Octave/min

IEC 600068-2-27, 15 g, 11 ms

Operating Temp.

32° F to 140° F (0° C to 60° C)

Relative Humidity

5% to 95% (without condensation)

Agency Certification

C-UL certified, UL 508 listed, CE

PROFIBUS conformance

PNO certified

Zertifikate

ATEX Letter of Conformity 83,59 kB Zuletzt geändert 12.05.2022
CB Safety 347,28 kB Zuletzt geändert 26.02.2020
CE Mark 91,88 kB Zuletzt geändert 22.02.2013
Country Approval - Eurasian Customs Union Conformity (EAC) (Wired) 1,92 MB Zuletzt geändert 10.07.2020
UL/cUL; Class 1, Div 2 1,12 MB Zuletzt geändert 27.02.2019
UL/cUL; Class 1, Div 2 (Canada) 1,14 MB Zuletzt geändert 27.02.2019
Declaration of Conformity 440,44 kB Zuletzt geändert 18.12.2020
Declaration of REACH Compliance 340,56 kB Zuletzt geändert 08.02.2021