The PLX51-PBM gateway provides connectivity to EtherNet/IP™, Modbus TCP/IP®, or Modbus® Serial networks for PROFIBUS DP networks by operating as either a Master or Slave device on the PROFIBUS DP network.
For easy integration to a Rockwell Automation Controller, the gateway and configuration software create dynamic AOI’s based on the user configuration to add logical tag names to the PLC project file. Thus, reducing the overall programming time for EtherNet/IP applications.
For configuration of Modbus TCP/IP or Modbus Serial Networks, the module will automatically map PROFIBUS DP data points to registers on a Modbus network.
With advanced tools such as PROFIBUS device discovery and a built-in PROFIBUS DP packet capture utility, PROFIBUS DP network commissioning time can be greatly reduced.
Dual Ethernet ports of the module can support either DLR (Device Level Ring) topology, or can be used as an embedded switch for flexible installation options.
With support for up to 1536 bytes of Input and Output data, and up to 4 EtherNet/IP connections to the processor, this module provides performance and data throughput back to the processor for even the most demanding of PROFIBUS applications.
When used as a PROFIBUS DP slave, the module can operate as 1 to 10 slaves, providing up to 1536 bytes of Input and Output Cyclic I/O data between EtherNet/IP, Modbus TCP/IP, or Modbus Serial devices and a PROFIBUS DP master.
The PLX51-PBS gateway provides connectivity to EtherNet/IP™, Modbus® TCP/IP, or Modbus® Serial networks for PROFIBUS DP networks by operating as a PROFIBUS DP slave.
For easy integration to a Rockwell Automation Controller, the gateway and configuration software create dynamic AOI’s based on the user configuration to add logical tag names to the PLC project file. Thus, reducing programming time.
For configuration of Modbus TCP/IP or Modbus Serial Networks, the module will automatically map PROFIBUS DP data points to registers on a Modbus network.
With advanced tools such as a built in PROFIBUS DP packet capture utility, PROFIBUS DP network commissioning time can be greatly reduced.
Dual Ethernet ports of the module can support either DLR (Device Level Ring) topology, or can be used as an embedded switch for flexible installation options.
With support for up to 1536 bytes of Input and Output data, and up to 4 EtherNet/IP connections back to the processor, this module provides performance and data throughput for even the most demanding of PROFIBUS applications.
As a PROFIBUS DP slave device, the module can emulate from 1 to as many as 10 slave DP nodes, providing up to 1536 bytes of Input and Output Cyclic I/O data between EtherNet/IP devices and a PROFIBUS DP master. This eliminates the need for using DPV1 messaging when more than 244 bytes of data needs to be exchanged between a PROFIBUS master and an EtherNet/IP network.
A conformal coating option is available for this product.
Der PLX51-HART-4I erlaubt den Nutzern eine einfache Verbindungen von existierenden HART Feldgerätene zu EtherNet/IP™, Modbus® TCP/IP, und DNP3 Ethernet Netzwerken.
Der PLX51-HART-4I unterstützt bis zu 4 Channels einer HART Kommunikation, als auch analoge (4-20 mA) Signale für echtzeitfähige Variablen von und zu den HART-kompatiblen Geräten.
Der PLX51-HART-4O erlaubt den Nutzern eine einfache Verbindungen von existierenden HART Feldgerätene zu EtherNet/IP™, Modbus® TCP/IP, und DNP3 Ethernet Netzwerken.
Das Modul kann für HART Ausgangsgeräte wie z.B. Stellungsregler innerhalb eines Ethernetnetzwerks genutz werden. Der PLX51-HART-4O unterstützt bis zu 4 Channels einer HART Kommunikation, als auch analoge (4-20 mA) Signale für echtzeitfähige Variablen von und zu den HART-kompatiblen Geräten
Der Modbus® TCP/IP zu PROFINET Controller Gateway erlaubt es Ihnen zwei Giganten der industriellen Automation durch sichere und schnelle Kommunikation zu verbinden. Der Gateway liefert der Modbus TCP/IP basierenden Steuerung die Möglichkeit bis zu 36 PROFINET RT Geräte wie z.B. Feld E/A, Antriebe, HMIs und Steuerungen zu kontrollieren.
Der PLX82-MBTCP-PNC Gateway ist ein „stand-alone“ Hutschienen Gerät, was mit Hilfe von zwei Ethernet Ports für Kommunikation, Fernzugriff und –wartung ausgelegt ist. Die SD-Karte (optional) kann für die Speicherung von Konfigurationsdateien für Recovery , Übertragung zu einem anderen Gateway oder als generisches Backup dienen.
Das PROFINET Device to Modbus Serial Gateway bietet bidirektionale Datenübertragung zwischen einer PROFINET-Steuerung und Modbus Serial-Geräten (RTU und ASCII). Jeder serielle Port kann entweder als Modbus Master oder als Modbus Slave konfiguriert werden. Die PROFINET-Schnittstelle arbeitet als PROFINET-Gerät (Slave).
Das PLX31-PND-MBS4 Gateway ist eine eigenständige Einheit, die auf einer DIN-Schiene montiert wird und Ethernet-Konnektivität für Netzwerkkommunikation, remote Konfiguration und Diagnose bietet. Der integrierte SD-Kartensteckplatz (SD-Karte optional) wird zum Speichern der Konfigurationsdateien verwendet, die ganz allgemein als Sicherungskopie der Konfiguration oder zur Notfallwiederherstellung genutzt werden können, indem die Konfiguration mithilfe dieser Dateien einfach auf ein anderes Gateway übertragen wird.
The PROFINET device to Modbus Serial gateway offers bi-directional data transfers between a PROFINET Controller and Modbus serial (RTU and ASCII) devices. The serial port can be configured as either a Modbus master or slave. The PROFINET interface operates as a PROFINET device (slave).
The PLX31-PND-MBS gateway is a stand-alone DIN-rail mounted unit that provides Ethernet connectivity for network communications, remote configuration, and diagnostics. The onboard SD Card slot (SD card optional) is used for storing configuration files that can be used for recovery, transferring the configuration to another gateway, or general configuration backup.
The Modbus TCP/IP to PROFINET device gateway offers bi-directional data transfer between a PROFINET Controller and Modbus TCP/IP networks. The Modbus TCP/IP driver uses multiple clients and servers for faster data throughput. The PROFINET driver operates as a PROFINET device (slave).
The PLX31-MBTCP-PND gateways are stand-alone DIN-rail mounted units that provide one Ethernet port for communications, remote configuration, and diagnostics. The onboard SD Card slot (SD card optional) is used for storing configuration files that can be used for recovery, transferring the configuration to another gateway, or general configuration backup.
Das Modbus TCP/IP to PROFINET Device Gateway bietet bidirektionale Datenübertragung zwischen einer PROFINET- Steuerung und Modbus TCP/IP-Netzwerken. Der Modbus TCP/ IP-Treiber nutzt zahlreiche Clients und Server für einen höheren Datendurchsatz. Der PROFINET-Treiber arbeitet als PROFINET- Gerät (Slave).
Die PLX32-MBTCP-PND-Gateways sind eigenständige Einheiten, die auf einer DIN-Schiene montiert werden und zwei Ethernet- Ports für Netzwerkkommunikation, remote Konfiguration und Diagnose bieten. Der integrierte SD-Kartensteckplatz (SD-Karte optional) wird zum Speichern der Konfigurationsdateien verwendet, die ganz allgemein als Sicherungskopie der Konfiguration oderzur Notfallwiederherstellung genutzt werden können, indem die Konfiguration mithilfe dieser Dateien einfach auf ein anderes Gateway übertragen wird.
The QuickServer line of communication gateways are designed to link building automation driven networks with industrial control networks. The QuickServer gateways are available with limits of up to 250, 500, or 1000 points of application data and connect building automation networks such as BACnet™ MS/TP, BACnet/IP, or JCI Metasys™ N2 with industrial control networks such as EtherNet/IP™, Modbus® RTU, or Modbus TCP/IP.
Benötigen Sie Daten von Ihren EtherNet/IP™ oder Modbus® TCP/IP basierenden Geräten und wollen mit Hilfe Ihres OPC UA Clients eine sinnvolle Analyse der Daten betreiben um so Betriebskosten einzusparen und die Produktion zu steigern? Der neue PLX32-EIP-MBTCP-UA Gateway von ProSoft Technology bringt EtherNet/IP, Modbus TCP/IP und OPC UA zusammen um sicher zu stellen, dass der Endkunde über einen Weg auf alle Daten von seinem ERP and MES System Zugriff hat. Der Modbus TCP/IP Treiber ist in der Lager mehrere Client- und Server-Verbindungen gleichzeitig für eine schnelle Übertragung der Daten herzustellen. Für eine einfache Integration und Inbetriebnahme für die Steuerungen von Rockwell Automation® wird ein „Add On Profile“ (AOP) zur Verfügung gestellt. Der höchst zuverlässige und sichere OPC UA Server unterstützt bis zu 10 OPC UA Sessions gleichzeitig,die den Zugriff auf das EtherNet/IP und Modbus TCP/IP Netzwerk erlauben. |
Was wäre wenn Sie die Möglichkeit hätten, die Daten Ihrer Steuerung zu speichern und diese für eine vorauschauende Wartung und Verbesserungen des Prozesses zu analysieren?
Der PLX51-DL-232 Datenlogger ist für Standorte mit limitierter Kommunikation bestens geeignet. OEM’s oder Maschinenbauer können Daten von ihren Maschinen ganz einfach speichern und auslesen um Betriebsstörungen zu identifizieren oder Prozesse effizienter zu gestalten. Der PLX51-DL-232 kann Daten von EtherNet/IP basierenden Steuerungen, DF1 seriellen Steuerungen oder von Modbus® basierten Modulen lesen und speichen. Der PLX51-DL-232 hat eine Kapazität um mehr als 16 Mio. Einträge in seinem internen Speicher zu beschreiben. Jeder Eintrag enthält einen Zeitstempel, ein Tag Name, den Daten Typ und dessen Wert.
The PLX51-DLplus-232 Data Logger is ideal for remote sites with limited communications that need to log data. OEMs can log their machine’s data to identify operational problems or efficiency improvements and can view this data online as trends via an integrated webserver. The trend data can be exported as a CSV file. The module supports REST API to collect JSON encoded data from the module that can be sent to other systems.
The PLX51-DLplus-232 can read and store data from EtherNet/IP™ PLCs, DF1 Serial PLCs and devices, or Modbus® PLCs and devices. The PLX51-DLplus-232 has the capacity to store over 16 million records in its solid-state non-volatile memory. Each stored record includes a Date Time stamp, Tag Name, Data Type, and Value.
Learn more about ProSoft’s Remote Connectivity Solutions.
IIntegration of Modbus TCP/IP® products into IEC 60870-5-104 networks can be a challenge, but not with ProSoft Technology’s PLX32-MBTCP-104 gateway.
The gateway has dual Ethernet ports, providing the option to have one Ethernet port communicating on both Modbus TCP/IP and IEC 60870-5-104 networks, or independent communication ports for each protocol.
The gateway provides powerful communications on the Modbus TCP/IP network, operating as either a Client or a Server to various devices such as PLC’s, Drives, HMI’s and various other equipment supporting the Modbus TCP/IP protocol.
On the IEC 60870-5-104 side of the communications, the gateway operates as a server, accepting commands from client devices such as a SCADA system or DCS system.
Mit den MVI56E Enhanced Modbus Master/Slave Communication Modulen lassen sich ControlLogix®-Prozessoren von Rockwell Automation® spielend einfach an Geräte anschalten, die das serielle Modbus RTU/ASCII-Kommunikationsprotokoll nutzen.
Das MVI56E-MCM und das MVI56E-MCMXT arbeiten als E/A-Module auf der ControlLogix-Backplane und sorgen dafür, dass die Modbus-Daten dem Prozessor als E/A-Daten angezeigt werden. Die Datenübertragung vom und zum Prozessor verläuft asynchron zur Kommunikation im Modbus-Netzwerk. Zwei unabhängig voneinander konfigurierbare serielle Ports können im selben oder in verschiedenen Modbus-Netzwerken arbeiten. Jeder Port kann als ein Modbus Master oder Slave konfiguriert werden und nutzt dieselbe vom Benutzer gesteuerte, 5000 Wörter umfassende Datenbank.
Die beiden Module sind von den Funktionen her identisch. Das MVI56E-MCM wurde für standardmäßige Prozessanwendungen konzipiert, während das MVI56E-MCMXT für die Logix-XT™-Steuerungsplattform entwickelt wurde und somit in Umgebungen eingesetzt werden kann, in denen extreme Bedingungen herrschen. Es hält höheren Betriebstemperaturen stand und weist zudem eine gleichmäßige Beschichtung auf, durch die es vor rauen oder ätzenden Bedingungen geschützt ist.
Die Module der Serie ILX34-MBS von ProSoft Technology eignen sich optimal für Anwendungen, die RS-232- oder RS-485 Modbus Serial- Konnektivität erfordern. Hierzu gehören u. a. SCADA- und Feldgeräte- Schnittstellenanwendungen. Jedes Modul kann in CompactLogix L1- Prozessoren oder 1734 Point I/O-Systemen verwendet werden. Außerdem können die Module als Modbus Master oder Slave konfiguriert werden.
Das MVI56E Modbus TCP/IP Client/Server Enhanced Communication Modul ermöglicht eine einfache Anschaltung der ControlLogix-Prozessoren von Rockwell Automation® an programmierbare Modicon-Automatisierungssteuerungen (PAC) und eine breite Palette von Modbus TCP/IP-kompatiblen Instrumenten und Geräten.
Zu den Erweiterungen des MVI56E gehören lokale und dezentrale Konfiguration und Diagnose über den Ethernet-Port des Moduls sowie die CIPconnect®-Technologie für das Bridging von Rockwell Automation ControlNet- und EtherNet/IP-Netzwerken.
Die Module MVI56E-MNET und MVI56E-MNETXT sind von den Funktionen her identisch. Das MVI56E-MNET wurde für standardmäßige Prozessanwendungen konzipiert, während das MVI56E-MNETXT für die Logix-XT™-Steuerungsplattform entwickelt wurde und somit in Umgebungen eingesetzt werden kann, in denen extreme Bedingungen herrschen. Es hält höheren Betriebstemperaturen stand und weist zudem eine gleichmäßige Beschichtung auf, durch die es vor rauen oder ätzenden Bedingungen geschützt ist.
The MVI56E-MCMR Enhanced Modbus Master/Slave Communication Module with Reduced Data Block allows Rockwell Automation® ControlLogix® processors to easily interface with devices using the Modbus RTU/ASCII serial communications protocol. Compatible devices include a wide variety of instruments, process measurement devices, popular brands of programmable logic controllers (PLCs) and programmable automation controllers (PACs).
The MVI56E-MCMR acts as an input/output module on the ControlLogix backplane, making Modbus data appear as I/O data to the processor. Backplane data transfers to and from the processor are asynchronous from communications on the Modbus network. Two independently-configurable serial ports can operate on the same or different Modbus networks. Each port can be configured as a Modbus Master or Slave, sharing the same user-controlled 5000-word database.
The MVI56E-MCMR utilizes a reduced Input/Output (I/O) data block for transferring data to and from a ControlLogix processor. This reduced data block makes it ideal for use in remote rack applications over ControlNet™. For EtherNet/IP™ applications where bandwidth is not an issue, it is strongly recommended to use the MVI56E- MCM.
Which of our Modbus TCP/IP modules is best for your application?
The Modbus TCP/IP Client/Server Enhanced Communication Module with Reduced Data Block allows Rockwell Automation ControlLogix processors to interface easily with Modbus TCP/IP-compatible devices, such as Modicon Programmable Automation Controllers (PACs) and a wide variety of Modbus TCP/IP-compatible instruments and devices.
The MVI56E-MNETR uses a reduced Input/Output (I/O) data image block size for transferring data between itself and a ControlLogix processor. This makes it ideal for remote rack applications using ControlNet or EtherNet/IP process networks. The module also works well for applications that require redundant ControlLogix processors.
MVI56E-MNETR enhancements include local and remote configuration and diagnostics through the module's Ethernet port, CIPconnect technology for bridging though Rockwell Automation ControlNet and EtherNetIP networks, and an on-board web server for access to module documentation and sample program files.
Which of our Modbus TCP/IP modules is best for your application?
The MVI56E Modbus TCP/IP Multi Client Enhanced Communication Module for Remote Chassis allows Rockwell Automation ControlLogix Programmable Automation Controllers (PACs) to interface easily with multiple Modbus TCP/IP server-compatible instruments and devices. The Multi Client module improves performance when controlling multiple servers on a Modbus TCP/IP network, by supporting up to 30 clients.
MVI56E enhancements include configuration and management through the module Ethernet port, CIPconnect technology for bridging through ControlNet and EtherNet/IP networks, and has a web server to access on-board documentation, Add-On Instructions, and sample program files.
This module uses a small I/O data image for transfer of data between the module and the ControlLogix processor, making it ideal for ControlNet or Ethernet applications with the module in a remote rack.
Das MVI69E-MBS Modbus Serial-Modul für CompactLogix™ wurde für alle Anwendungen konzipiert, die Modbus Serial-Konnektivität erfordern. Dieses Modul bietet ein Add-on Profile und eine Add-on Instruction, um die Inbetriebnahmezeiten zu verkürzen. Das MVI69E-MBS verfügt über zwei serielle Ports und kann Master- und/oder Slave-Konnektivität unterstützen, um die Anschaltung an eine Vielzahl von Geräten zu ermöglichen, die mit dem Modbus-Protokoll arbeiten.
Das MVI69L-MBS Modbus Serial-Modul für die Familie der CompactLogix™-Steuerungen wurde für kleinere Anwendungen konzipiert, in denen die Kommunikation zwischen einigen wenigen Modbus Serial-Geräten erforderlich ist. Dieses Modul bietet ein Add-on Profile und eine Add-on Instruction, um die Inbetriebnahmezeiten zu verkürzen. Das MVI69L-MBS verfügt über einen einzelnen seriellen Port und kann entweder Master- oder Slave-Konnektivität unterstützen, um die Anschaltung an eine Vielzahl von Geräten zu ermöglichen, die mit dem Modbus-Protokoll arbeiten.
Das MVI69E-MBTCP Modbus TCP/IP-Modul für die Familie der CompactLogix™-Steuerungen wurde für solche Anwendungen konzipiert, die Modbus TCP-Konnektivität erfordern. Dieses Modul bietet ein Add-On Profile und eine Add-on Instruction, um die Inbetriebnahmezeiten zu verkürzen. Das MVI69E-MBTCP verfügt über einen einzelnen Ethernet- Port für Diagnose- und Anwendungsdaten. Das Modul unterstützt sowohl Client- als auch Server-Konnektivität für die Anschaltung an eine Vielzahl von Geräten, die mit dem Modbus-Protokoll arbeiten.
Das MVI69L-MBTCP Modbus TCP/IP-Modul eignet sich ideal für kleinere Anwendungen, in denen die CompactLogix L2-Steuerungen zum Einsatz kommen. Das Modul bietet ein Add-on Profile und eine Add-on Instruction, um die Inbetriebnahmezeiten zu verkürzen.
Das MVI69L-MBTCP verfügt über einen einzelnen Ethernet-Port für Diagnose- und Anwendungsdaten. Es unterstützt sowohl Client- als auch Server-Konnektivität für die Anschaltung an eine Vielzahl von Geräten, die mit dem Modbus TCP/IP-Protokoll arbeiten.
Das Modbus® TCP/IP to Siemens Industrial Ethernet Communication Gateway von ProSoft Technology ermöglicht eine bidirektionale Hochgeschwindigkeits-Datenübertragung zwischen Modbus® TCP/IP-Steuerungen und den programmierbaren Automatisierungssteuerungen (PAC) S7-400, S7-300, S7-200 und S7-1200 von Siemens®.
Zudem umfasst das Gateway verschiedene Funktionalitäten - so u. a. die Datenpriorisierung -, die eine einfache Integration, kürzere Inbetriebnahmezeiten und eine optimierte Leistung ermöglichen
ProSoft Technology’s Modbus® TCP/IP to Modbus® Serial four-port Serial gateway allows high-speed bi-directional data transfers between Modbus® TCP/IP-enabled PACs and Modbus® Serial devices. Modbus® Serial devices are widely used in nearly every industry and include SCADA systems and Power Monitors. Four Serial ports allow for connectivity of up to 400 Modbus® Serial devices, reducing the amount of gateways required for your application.
In addition, the gateway includes several features that allow for simplified integration, reduced commissioning time and optimized performance.
A conformal coating option is available for this product.
ProSoft Technology’s Modbus® TCP/IP to Modbus® Serial communication gateway allows high-speed bi-directional data transfers between Modbus® TCP/IP-enabled PACs and Modbus® Serial devices. Modbus® Serial devices are widely used in nearly every industry and include SCADA systems and Power Monitors.
In addition, the gateway has several features that allow simplified integration, reduced commissioning time and optimized performance.
A conformal coating option is available for this product.
Das EtherNet/IP™ to Modbus® TCP/IP Kommunikations-Gateway von ProSoft Technology ermöglicht eine bidirektionale Hochgeschwindigkeits-Datenübertragung zwischen EtherNet/IP™- fähigen Steuerungen oder Geräten und Modbus® TCP/IP-fähigen Steuerungen oder Geräten. Unser Modbus® TCP/IP-Treiber bietet Multi-Client- und Multi-Server-Funktionalität, wodurch sich die Datenübertragung beschleunigt.
Zudem umfasst das Gateway verschiedene Funktionalitäten - so u. a. die Datenpriorisierung -, die eine einfache Integration, kürzere Inbetriebnahmezeiten und eine optimierte Leistung ermöglichen.
ProSoft Technology’s EtherNet/IP™ to Modbus® Serial communication gateway allows high-speed bi-directional data transfers between EtherNet/IP™ PACs or devices and Modbus®-enabled PACs or devices.
EtherNet/IP™ PACs include Rockwell Automation® ControlLogix® and CompactLogix™, as well as several Schneider Electric® controllers. Modbus® Serial devices are widely used in nearly every industry and include SCADA systems and Power Monitors.
The gateway includes several features that allow for simplified integration, reduced commissioning time and optimized performance
Das EtherNet/IP™ to Modbus® Serial Communication Gateway von ProSoft Technology ermöglicht eine bidirektionale Hochgeschwindigkeits- Datenübertragung zwischen programmierbaren EtherNet/IP™-fähigen Automatisierungssteuerungen oder -Geräten und Modbus®-fähigen programmierbaren Automatisierungssteuerungen oder Geräten.
Zu den programmierbaren EtherNet/IP™-fähigen Automatisierungssteuerungen gehören u. a. die Rockwell Automation®- Steuerungen der Serien ControlLogix® und CompactLogix™ sowie verschiedene Steuerungen von Schneider Electric®. Modbus® Serial- Geräte sind in praktisch jeder Branche weit verbreitet und umfassen SCADA-Systeme und Netzmonitore. Vier Ports ermöglichen den Anschluss von bis zu 400 Modbus® Serial-Geräten, wodurch sich die Zahl der für Ihre Anwendung erforderlichen Gateways reduziert.
Zudem umfasst das Gateway verschiedene Funktionalitäten, die eine einfache Integration, kürzere Inbetriebnahmezeiten und eine optimierte Leistung ermöglichen.
Die Module der Serie ILX34-MBS von ProSoft Technology eignen sich optimal für Anwendungen, die RS-232- oder RS-485 Modbus Serial- Konnektivität erfordern. Hierzu gehören u. a. SCADA- und Feldgeräte- Schnittstellenanwendungen. Jedes Modul kann in CompactLogix L1- Prozessoren oder 1734 Point I/O-Systemen verwendet werden. Außerdem können die Module als Modbus Master oder Slave konfiguriert werden.
The PLX51-DNPS gateways provide intelligent routing between DNP3 (Distributed Network Protocol) and either EtherNet/IP™ or Modbus® protocols. The gateways support Ethernet and Serial communications.
PLX51-DNPS gateway is the DNP3 Outstation or Slave.
The PLX51-DNPS allows the user to integrate DNP3 devices over a secure link into a Logix system with minimal effort. No copying or mapping of data in the Logix controller is required as the PLX51-DNPS writes directly into Logix tags.
The PLX51-DNPS allows users to integrate the gateway into a Modbus TCP/IP or serial network. The gateway supports Modbus TCP/IP Client and Server and Modbus RTU protocols.
The PLX51-DNPS module provides DNP3 Secure Authentication 5 which enables the user to connect DNP3 devices to a Logix platform securely. The module also provides a range of diagnostics, statistics and a DNP3 traffic analyzer to assist with fault-finding.
The PROFIBUS PA gateway allows the user to interface PROFIBUS PA DPV0/DPV1 to either EtherNet/IP™ or Modbus® devices.
When configured as a Master, the PA Link can exchange up to 2 kilobytes of PROFIBUS PA device and status data.
The PA Link has two Ethernet ports for a Linear or Ring (Device Level Ring – DLR) Ethernet topology. The Ethernet ports can also be configured for port mirroring, allowing for better fault analysis.
The PA Link can synchronize to an NTP Server allowing for automatic time synchronization. It also supports an onboard non-volatile event log for improved fault finding. The PA Link has a built-in Power Conditioner which can supply up to 420 mA. The power conditioner is protected against a configurable overcurrent limit. The module also has a configurable built-in Fieldbus terminator.
The PA Link provides a range of statistics and tools to provide a detailed diagnostic overview of each PA Link, which speeds-up fault finding. The Slate Configuration Utility allows the user to perform a PROFIBUS PA packet capture of the running Fieldbus which can be used to analyze the bus behavior and packets received. The PA Link also provides global and device specific statistics.
The XPosition module provides connectivity between high precision GPS and inertial navigation devices to Rockwell Automation’s Logix (ControlLogix® and CompactLogix™) family of controllers.
The module operates in a Logix “owned” mode. With a Logix connection the input and output assemblies will provide additional diagnostics information which will be available in the Logix controller environment.
The module uses an external GPS receiver to provide accurate position information. The external GPS or inertial navigation device provides various accuracy estimates allowing the user to make informed decisions for high precision position and velocity applications.
The XPosition module supports dual antenna receivers, allowing users to access Yaw, Tilt and Heading data.
The integrated webserver provides detailed diagnostics of system configuration and operation, including the display of GPS time, position, and velocity without the need for any additional software.
Check out a successful application with this solution: OEM Adds a Position Check to Mining Machine
The Time Sync module provides Precision Time Protocol (PTP - Grand Master) and NTP Time services. This enables precision time synchronization for Logix Controllers and HMI systems. It can also provide GPS position and velocity data. The module uses an on-board GPS receiver to provide accurate time and position information.
Because the module is stand-alone and connects to various devices over an Ethernet network the module can be placed as close as possible to the antenna position removing the need for costly low-loss coaxial cables that was traditionally needed to connect the GPS antenna to the module. The on-board GPS receiver also provides velocity and odometer reading allowing the user to implement the module in various vehicle and tracking applications. The GPS accuracy information provided allows the user/controller to make calculated decision when looking at the position, velocity, or odometer information.
A built-in webserver provides detailed diagnostics of system configuration and operation, including the display of GPS time, position, and velocity without the need for any additional software.
The CANopen® Router provides intelligent data routing between either EtherNet/IP™ or Modbus TCP/IP® and the CANopen bus network. This allows the user to integrate CANopen devices into a Rockwell® Logix platform (e.g. ControlLogix® or CompactLogix™) or any Modbus Master device with minimal effort.
The module can be configured to be either a Master or Slave allowing the user to not only integrate CANopen devices into a Logix or Modbus system, but to also allow the user to use Logix or Modbus devices in an existing CANopen network (by using the CANopen Router in Slave mode). In a Logix system the module uses Direct-To-Tag technology allowing CANopen devices to exchange data with a Logix controller without the need to write any ladder or application code in Studio 5000.
The module also provides a range of statistics to simplify the diagnostic process as well as a CANopen packet capture for remote diagnosis. A built-in webserver provides detailed diagnostics of system configuration and operation, including the display of CANopen operation and communication statistics, without the need for any additional software.
Das Modbus TCP/IP to IEC 61850 Gateway ermöglicht die Kommunikation zwischen den Intelligent Electronic Devices (IEDs) in einem IEC 61850-Netzwerk und speicherprogrammierbaren Steuerungen (SPS) oder programmierbaren Automatisierungssteuerungen (PAC) in einem Modbus TCP/IP-Netzwerk.
Das mit dem Gateway mitgelieferte Konfigurationsdienstprogramm nutzt IED- Konfigurationsdateien, um komplexe IEC 61850-Datenstrukturen zu importieren. Das Dienstprogramm erzeugt Variablendateien und Funktionsblockdateien für den Import in Unity-Pro-Projekte für Quantum- oder M340-Prozessoren.
Die IEC 61850 ist die internationale Norm, die die Hardware- und Kommunikationsanforderungen für alle Geräte in einer Stationsautomatisierung definiert. Die durch die IEC 61850 auferlegten standardisierten Namenskonventionen verbessern die Interoperabilität zwischen Systemen, die von verschiedenen Herstellern stammen oder von mehreren Systemintegratoren erstellt wurden.
Click Here for Additional Modbus Gateway Products
“Understanding Modbus Serial and TCP IP” is a quick tutorial for Rockwell Automation users on the Modbus protocol. The video is a great tool for anyone who is unfamiliar with how Modbus Serial and TCP IP operate, including information about function codes and data structures.